13001 Serial ISA - Basic board, 1kV isolated
Price per Unit (piece):
735,00 DKK
Serial motherboard for adding
W&T interface modules, 1kV isolation

Application:
PC as PLC programming device
Background information:
There are many cases where it is necessary to equip the ports of an interface card with different port models. It may for example be necessary to use COM1 as a 20mA programming interface for a PLC, as the software used only supports this port, while COM2 is connected to a serial RS232 mouse. For such requirements, W&T provides a very smart solution without any need for additional external hardware. The module concept of the serial W&T PC cards allow you to freely select the interface model, as the PC card mainboard is equipped with pluggable modules that convert the internal TTL signals into interface signals. The combined interface cards are supplied fully configured according to your specifications and are ready for installation. You can change a built-in port at any time by simply replacing the interface module.
| Number of ports: |
|
2 galvanically isolated slots for interface modules |
| UART: |
|
16550 with FIFO |
| Base addresses: |
|
03F8H, 02F8H, 03E8H, 02E8H |
| Interrupts: |
|
IRQ 3..7, IRQ 9..12 |
| Baud rate: |
|
50..115,200 baud |
| Data format: |
|
any format |
| Signal lines: |
|
RxD,TxD,RTS,CTS,DSR,DCD,DTR,RI |
| Adapters: |
|
12-pin header with 2mm spacing |
| Galvanic isolation: |
|
Isolation voltage min. 1 KV DC between PC and serial ports |
| Power supply: |
|
depending on applied module |
| Ambient temperature: |
|
Storage: -40..+70°C, Operation: 0..+70°C |
| Permissible relative humidity: |
|
0..95% RH (non-condensing) |
| Dimensions: |
|
165 x 106 mm |
| Weight: |
|
approx. 150 g |
| Delivery: |
|
1x Serial ISA-Basic board, 1kV isolated |
| Special features: |
|
Card may be fitted with plug-in modules of different interface types |
Product properties:
- Upgrading of PCs with high-speed serial ports
- 20mA, RS232, RS422, RS485 and profibus can be combined on one card
- Manual configuration by means of DIL switch
- Flexible configuration
- Standard base addresses COM1-COM4
- Custom base addresses possible
- Interrupts IRQ3-IRQ7, IRQ9-IRQ12
- UART 16550 with FIFO
- 1kV electrical isolation to the PC and between the ports
- Software compatible with standard RS232 cards
- No additional driver software required
- Conforms to standards both in office and industrial environments:
- Increased noise immunity for industrial areas
- Stricter noise emission for residential and commercial areas